FP01 Hydraulic Solenoid Valves, Auto Reset

FP01 Hydraulic Solenoid Valves, Manual Reset & Manual Override, Direct Acting, up to 690 bar, 1 lpm, Cv 0.01, Ex emb, Ex d & Ex ia
download pdf brochure

These products are part of the preferred supply – for full selection please refer to catalogue.

solenoid valve FP01/S1/M/32/NC/S/74AT4-24D/ML/36 48 hour despatch logo
3 way 2 position, Direct Acting, Normally Closed,
24Vdc, Manual Reset. 3.6 Watt, Cv 0.01, 345 bar.
ATEX ex logo II 2 GDc, Ex emb IIC T4 Gb
IECEx Ex emb IIC T4 Gb
-25ºC to +50ºC
IP66/IP67 & NEMA 4X
   
FP01/S1/M/32/NC/S/77A-24D/ML/30 48 hour despatch logo
3 way 2 position, Direct Acting, Normally Closed,
24Vdc, Manual Reset. 3.0 Watt, Cv 0.01, 345 bar.
ATEX ex logo II 2 GD, Ex d IIC T6
IECEx Ex d IIC T6
-60ºC to +40ºC
IP66/IP67 & NEMA 4X
   
FP01/S1/M/32/NC/S/78A-155/ML 48 hour despatch logo
3 way 2 position, Direct Acting, Normally Closed,
Manual Reset. 155 Ohms, Cv 0.01, 345 bar.
ATEX ex logo II I GD, Ex ia IIC T6 Ga
IECEx Ex ia IIC T6 Ga
-60°C to +60°C
IP66/IP67 & NEMA 4X
 
 
solenoid valve FP01/S2/M/32/NC/S/74AT4-24D/ML/36 48 hour despatch logo
3 way 2 position, Direct Acting, Normally Closed,
24Vdc, Manual Reset. 3.6 Watt, Cv 0.01, 517 bar.
ATEX ex logo II 2 GDc, Ex emb IIC T4 Gb
IECEx Ex emb IIC T4 Gb
-25ºC to +50ºC
IP66/IP67 & NEMA 4X
   
FP01/S2/M/32/NC/S/77A-24D/ML/30 48 hour despatch logo
3 way 2 position, Direct Acting, Normally Closed,
24Vdc, Manual Reset. 3.0 Watt, Cv 0.01, 517 bar.
ATEX ex logo II 2 GD, Ex d IIC T6
IECEx Ex d IIC T6
-60ºC to +40ºC
IP66/IP67 & NEMA 4X
   
FP01/S2/M/32/NC/S/78A-155/ML 48 hour despatch logo
3 way 2 position, Direct Acting, Normally Closed,
Manual Reset. 155 Ohms, Cv 0.01, 517 bar.
ATEX ex logo II I GD, Ex ia IIC T6 Ga
IECEx Ex ia IIC T6 Ga
-60°C to +60°C
IP66/IP67 & NEMA 4X
 
 
solenoid valve FP01/S3/M/32/NC/S/74AT4-24D/36 48 hour despatch logo
3 way 2 position, Direct Acting, Normally Closed, 24Vdc,
Auto Reset. 3.6 Watt, Cv 0.01, 690 bar.
ATEX ex logo II 2 GDc, Ex emb IIC T4 Gb
IECEx Ex emb IIC T4 Gb
-25ºC to +50ºC
IP66/IP67 & NEMA 4X
   
FP01/S3/M/32/NC/S/77A-24D/30 48 hour despatch logo
3 way 2 position, Direct Acting, Normally Closed, 24Vdc,
Auto Reset. 3.0 Watt, Cv 0.01, 690 bar.
ATEX ex logo II 2 GD, Ex d IIC T6
IECEx Ex d IIC T6
-60ºC to +40ºC
IP66/IP67 & NEMA 4X
   
FP01/S3/M/32/NC/S/78A-155 48 hour despatch logo
3 way 2 position, Direct Acting, Normally Closed,
Auto Reset. 155 Ohms, Cv 0.01, 690 bar.
ATEX ex logo II I GD, Ex ia IIC T6 Ga
IECEx Ex ia IIC T6 Ga
-60°C to +60°C
IP66/IP67 & NEMA 4X
 
 
solenoid valve FP01/S1/S1/M/32/NC/S/74AT4-24D/SB/M/36 3 way 2 position, Direct Acting, Normally Closed,
24Vdc, pulse operated, bi-stable, hydraulically
latched, fail to close on loss of pressure, Manual
Override Spring Return. 3.6 Watt, Cv 0.01, 345 bar.
ATEX ex logo II 2 GDc, Ex emb IIC T4 Gb
IECEx Ex emb IIC T4 Gb
-25ºC to +50ºC
IP66/IP67 & NEMA 4X
Wider range of options shown in the catalogue.
   
FP01/S2/S2/M/32/NC/S/77A-24D/SB/M/30 3 way 2 position, Direct Acting, Normally Closed,
24Vdc, pulse operated, bi-stable, hydraulically
latched, fail to close on loss of pressure, Manual
Override Spring Return. 3.0 Watt, Cv 0.01, 517 bar.
ATEX ex logo II 2 GD, Ex d IIC T6
IECEx Ex d IIC T6
-60ºC to +40ºC
IP66/IP67 & NEMA 4X
Wider range of options shown in the catalogue.
   
FP01/S3/S3/M/32/NC/S/78A-155/SB/M 3 way 2 position, Direct Acting, Normally Closed,
pulse operated, bi-stable, hydraulically
latched, fail to close on loss of pressure, Manual
Override Spring Return. 155 Ohms, Cv 0.01,690 bar.
ATEX ex logo II I GD, Ex ia IIC T6 Ga
IECEx Ex ia IIC T6 Ga
-60°C to +60°C
IP66/IP67 & NEMA 4X
Wider range of options shown in the catalogue.